Temperature and Humidity Data Logger for Managing Production Plants and Agricultural Sites
Functionality | [Used as standalone product (Data collected manually) ] Windows PC or Windows tablet (CD-R with software included) Android smartphone or Android tablet terminal (Software can be downloaded free of charge from Google Play.) *Communication range varies with the performance of the computer or tablet (up to a line-of-sight distance of roughly 30 m) [Used as logging module (Real-time measurement) ] Device can be used as an LR8410 logging module to record and display data in real time and to control up to 7 units, Communication distance: 30 m |
|||||
---|---|---|---|---|---|---|
Number of channels | 2 ch for temperature + 2 ch for humidity (2 sensors can be attached) | |||||
Measurement items | Temperature, Humidity | |||||
Measurable Range | [Temperature] -40 ˚C to 80 ˚C, Range 100˚C f.s., Max. resolution 0.1˚C [Humidity] 0 to 100% RH, Range 100% RH f.s., Max. resolution 0.1%RH |
|||||
Measurement accuracy (using Z2010/ Z2011) |
[Temperature basic accuracy] ±0.5 ˚C (10 to 60 ˚C) *If outside above temperature range: Add 0.015 ˚C/ ˚C (-40 to 10 ˚C) or 0.02˚ C/ ˚C (60 to 80 ˚C) [Humidity basic accuracy] ±3% RH (20 to 30 ˚C, 20 to 90% RH), Hysteresis: ±1% RH (Added to the humidity measurement accuracy) |
|||||
Display items | Measurement value, date, time, number of recorded data, maximum value, minimum value, and average value | |||||
Functions | Alarm, Scaling, Recording operation hold function, Erroneous operation prevention, Comment recording function, Power saving function, Authentication function, Free run | |||||
Recording | [Capacity] 500,000 data items for each channel [Mode] Instantaneous value [Interval] 0.5 to 30 sec, 1 to 60 min, 14 selections | |||||
Power source | AC Adapter Z2003 (100 to 240 V AC, 50/60 Hz), AA alkaline batteries (LR6) ×2, External power 5 to 13.5 V DC (can also be supplied from USB bus power, with a conversion cable) | |||||
Continuous operating time ([Capacity] 500,000 data items for each channel) (23˚C) |
3.5 months (Recording interval of 1 min, Bluetooth® OFF), 20 days (Recording interval of 1 sec, Bluetooth® ON), 5 days (Recording interval of 0.5 sec, during real-time measurement with the LR8410) | |||||
Dimensions and mass | 85 mm (3.35 in) W × 61 mm (2.40 in) H × 31 mm (1.22 in) D (Excluding protrusions), 95 g (3.4 oz) (Not including the battery) | |||||
Included accessories | CD-R ×1 (Instruction Manual, Logger Utility, Wireless Logger Collector), Measurement Guide ×1, Caution for Using Radio Waves ×1, AA alkaline batteries (LR6) ×2 |